Features

  • Submersible Sewage Pump.
  • Waterproof cable prevent water infiltration.
  • Built-in thermal motor protector to prevent over-loading.
  • Equipped with double mechanical seals (Silicon carbide).
  • Influent Pumping is combined treatment plants and waste water applications.
  • Sewage waste water.
  • Pump house is sewer systems.

Technical Data

Applications

  • Effluent pumping in industrial wastewater treatment plants.
  • Sewage wastewater and solid treatment in various factories and building sites.
  • Food processing factory.
  • Confined livestock feeding industry.
  • Pulp and paper factory.
  • Residential houses.
  • Restaurants and shops.
  • Markets and supermarkets.

The automatic connecting device performs connection and disconnection between a pump and piping only by lifting the pump down I up along guide pipes, so the maintenance and inspection work can be done without entering the pump sump.

Performance Curve

Model Motor Pump
Power Phase Volt Revolution Pump Outlet Discharge Max. Head Max. Flow Solid Passage
HP KW PH V Rpm Inch Mm Ft Gal/Min Inch
GSTO-332 3 2.2 3 460V 1800 3 80 46 346 1.6 x 1.9

Dimensions

Size (inch) Weight (lbs.)
A B C D E F G H I
29.7 14.4 12.2 4.6 11.1 24.9 28.4 10.6 Ø 3.1 (Ø 3.9) 253

Parts and Materials

Components